1. Application
This specification shall apply to the lamp driver M66WBU-M to operate a ArcMeister™ 60W lamp.
This driver is designed and adjusted for the metal halide lamp.
2. Standard Applied

The lamp driver is designed to meet these standards when mounted in the set.

[2-1] Safety Standard
  UL60950, IEC60950
[2-2] EMI
  FCC Part18 class B

Note: This product is capable to restrike itself in 45 sec. however, it is not recommended that you re-start the ballast while the lamp is still warmed up, as it will cause the electrode to wear out and as a result, it will shorten the life of the lamps. The most ideal re-stike time in order to maintain the lamp life is 45 sec. or longer.


3. General Specification
Category
Specification
Remarks

Cooling Method

Self-Cooling System under 60W
Forced Air Cooling recomended for over 60W.
 

Operation Ambient Temperature

0°C - 60°C (32F-140F)  

Operational Relative Humidity

10-80%RH no condensation

Storage Ambient Temperature

-20°C - 70°C (60F-158F)  

Storage Relative Humidity

5-90%RH no condensation

4. Electrical Characteristics to Operate 60W
[4-1] INPUTS

Category
Specification
Remarks

Rated Input Voltage

AC100-240V Frequency 50-60Hz

Input Voltage Range

AC90-264V Frequency 48-62Hz

Input Power

80W ± 5%  

Input Current

1.0A at AC 100W

[4-2] OUTPUTS
Category
Specification
Remarks

Output Power of BT

Vs inputs 60W ± 5% Vin = AC90-264V (VL=55V)
Vs output 60W ± 5% VL=45-100V

Peak Voltage during ignition

10-20kV Vin = AC90-264V

Cycle of HV during ignition

60 cycle Vin=AC100V

Ignition time

below 2 Seconds Vin=AC100V

Power Control Range

60W ± 25% By internal VR
40W ± 5W By external VR (min)
80W ± 8W By external VR (max)
40W ± 5W By power control signal (0V)
80W ± 8W By power control signal (5V)

DC Fan Output

11.3-12.7V IF=0.25A (max)

4. Reliability
[8-1] MTBF (Mean Time Between Failure) : 10,000 h and more
  MTTF (Mean Time to Failure): 50,000 h
 


Operating Condition
Ambient Temperature: 60°C (140°F), input voltage: 100V AC 50Hz


[8-2] Environment of Examination

After the following environment examination, in the normal operating temperature.

Electrical Characteristics

Test
Condition
High Temperature Operation Test
(Tested 200hrs)
Ambient Temperature: 60°C (140°F)
Input: AC90V 50Hz
Load: 80W
Low Temperature Operation Test
(Tested 96hrs)
Ambient Temperature: 40°C (104°F)
Input: AC90V 50Hz
Load: 80W
High Temperature & High Humidity Operating Test
(Tested 96hrs)
Ambient Temperature: 40°C, Humidity: 95%RH
Input: AC90V 50Hz
Load: 80W
High Temperature Stability
(Tested 96hrs)
Ambient Temperature: 80°C (176°F)
Low Temperature Stability
(Tested 96hrs)
Abient Temperature: -20°C (-4°F)
High Temperature & High Humidity Stability
(Tested 200hrs)
Abient Temperature: 40°C (104°F)
Thermal Shock
(Tested 10 cycles)
Ambient Temperature: -20°C/30Min to 70°C/30Min. Temperature rise/fall within 5Min. to next temperature
Cyclic Temperature Operation
(Tested 10000 cycles)
Ambient Temperature: 25°C (77°F)
Input: 90V AC 50Hz
Load: 80W, ON/2Min OFF/5Min
Vibrations
(Tested 1hr each for 3 directions X,Y, and Z)
Acceleration: 1.96m/S2 (constant)
Frequency Range: 10-55Hz
Directions: 3 (XYZ)
Shock
(Ballast fixed on wooden board)

Tested the intensity when dropped above 1.18 inch from ground