12V and 24V available
Switchable 40W / 60W
Compact and Portable use
Dimension: 135mm x 50mm |
Download Datasheet
|
| |
| 1. Application |
|
This specification shall apply to the lamp driver M66WBU-M
to operate a ArcMeister™ 60W lamp. This driver
is designed and adjusted for the metal halide lamp.
|
|
|
|
| 2. Standard Applied |
|
The lamp driver is designed to meet these standards when
mounted in the set.
|
| [2-1] Safety
Standard |
| |
UL60950,
IEC60950, CSA905, EN60950, EN60065 |
| [2-2] EMI |
| |
VCCI
CLASS2, FCC CLASSB, EN55022 CLASSB, EN50082-1
| |
| 3. General Specification |
|
Category |
Specification |
Remarks |
|
Cooling Method
|
Forced Air-Cooling System
|
0.3m3/Min |
|
Operation Ambient Temperature
|
0°C - 60°C (32F-140F) |
|
|
Operational Relative Humidity
|
10-80%RH |
no condensation |
|
Storage Ambient Temperature
|
-20°C - 70°C (60F-158F) |
|
|
Storage Relative Himidity
|
5-90%RH |
no
condensation |
| |
4. Electrical
Characteristics [4-1] INPUTS |
|
Category |
Specification |
Remarks |
|
Rated Input Voltage
|
DC 11V-18V |
DC 12V-15V |
|
Aufnahme
|
Normal Output
|
73W ± 5% |
Input Voltage DC15V (49 Ω
impedance)
|
Low-Mode [J4-geschl.] |
48W ± 5% |
Input Voltage DC15V (75.6 Ω
impedance)
|
|
Input Voltage Ripple
|
Max 3% |
f=10kHz |
|
Input Current
|
Max 6.5A |
Max 10A@ 0.5m/Sec
|
|
| [4-2] OUTPUT |
|
Category |
Specification |
|
|
Output Power
|
Vs
Inputs |
60W ±
5% |
VIn=DC11V-18V
VL=70V |
| Vs
Outputs |
60W ± 5% |
VL=55V-100V,
VIn=DC15V [VL=100V-120V VsOut: -8%,
+5%] [VL=45V-55V, Vsout: +5%, -10%] |
Low-Mode J4-Short
Mode |
40W ±7% |
VL=55V-100V,
VIn=DC15V [VL=100V-115V VsOut: -10%,
+5%] [VL=45V-55V, Vsout: +5%, -12%] |
|
Peak Voltage During Ignition
|
5.75V0-P |
VIn=DC15V,
5.0-7.5kV0-P J6 output: btwn +HV and -HV |
|
Cyvle of HV During Ignition
|
70 cycles |
VIn=DC15V |
|
Ignition Time
|
weniger als 4.5
sec. |
VIn=DC15V 3.0-4.5
sec.
|
| |
| [4-3] Outputs Protection |
|
Category |
Specification |
Remarks |
|
Short Current Protection
|
2.0 A |
Automatic re-strike
|
|
Over Voltage Protection
|
150 ± 20V |
|
|
Thermal Protection
|
45±15 °C (112 ± 59° F)
|
Circuit NoTH1
Heat Detect |
|
Low-Input Voltage Protection
|
10 ± 0.5V |
|
| |
5. Reliability
| [5-1] |
MTBF
(Mean Time Between Failure) : 10,000 h and more
|
| |
MTTF
(Mean Time to Failure): 50,000 h
|
Operating condition Ambient Temperature: 60°C (140°F), input voltage:
DC15V Output: 60W Rated load condition 60
Ohm (resistance load)
[5-2]
Environment of Examination After the following environment examination, in the normal
operating temperature.
6.Electrical
Characteristics
|
Test
|
Condition |
High Temperature Operation Test (Tested 200hrs) |
Ambient Temperature:
60°C (140°F) |
| Input: 15VDC |
| Load: 60W |
Low Temperature Operation Test (Tested 96hrs) |
Ambient Temperature:
0°C (32° F) |
| Input: 15VDC |
| Load: 60W (no
condensation) |
High Temperature & High Humidity Operating Test (Tested 200hrs) |
Ambient Temperature:
0°C (32°F), Humidity: 95%RH |
| Input: DC15V |
| Load: 60W
|
High Temperature Stability (Tested 96hrs) |
Ambient Temperature: 80°C (176°F)
|
Low Temperature Stability (Tested 96hrs) |
Ambient Temperature:
-20°C (-4°F) |
High Temperature & High Humidity Stability (Tested 200hrs) |
Ambient Temperature:
40°C (104°F) , Humidity: 95%RH (no condensation) |
Thermal Shock (Tested 10 cycles) |
Ambient Temperature:
-20°C/30Min to 70°C/30Min. Temperature rise/fall within 5 Min. |
Cyclic Temperature Operation (Tested 10,000 cycles) |
Ambient Temperature:
Room Temperature |
| Input: DC15V
|
| Load: 60W, ON/1Min. -
OFF/1Min. |
Vibrations (Tested 1hr each for 3 directions X,Y, and Z) |
Acceleration:
1.96m/S2 (constant) |
| Frequency Range:
10-55Hz |
| Directions: 3(XYZ) |
Shock (Ballast fixed on wooden board) |
Tested the intensity when dropped above 1.18 inch from ground.
|
|
| | |