Contact
ArcMeister Lamps
  Highe-Output
  High-CRI
  Highe Stability
Ballast
  AC
  DC
  Exterior
FGM Technology
Fiber Box PTX-60
Lamp Comparison
  TechnoLab GmbH
is exclusive
PEC Lamp distributor for Europe
 



TechnoLab GmbH
Am Borsigturm 46
13507 Berlin
Tel:(030)43033160
Fax:(030)43033169
 
Green Energy
Lighting Corp

11266 Monarch St.
Garden Grove,
CA 92841
Ph:800-211-5483
Fx:714-889-4128


Universal 90V-264V AC
Dimmable Range 60W-100W
Instant Start at 90% light in 20 s.
Hot re-strike in 1 s.


Download Datasheet

 
New Features
+ Durable in extreme temperature range : -4°F - 140°F
+ Produces less noise
+ Low electricity leakage
+ Instant re-strike

New Conzept

Note: This product is capable to restrike itself in 45 sec. however, it is not recommended that you re-start the ballast while the lamp is still warmed up, as it will cause the electrode to wear out and as a result, it will shorten the life of the lamps. The most ideal re-stike time in order to maintain the lamp life is 45 sec. or longer.

Category
Specification
Remarks

Water Proof

For outdoor use

Aluminium die-case model & urethane potting

 
Temperature

Tested and quaranteed to be used safely at sea and outdoor

-20°C - 60°C  

Noiseless/Dustless

No fan required for lamp/ ballast

Self Cooling System

Lamp is securely protected

Starter

Instant re-strike

Lights up in 3 s. at max 15Kv  
Dimmer Function Dimmable 60W-100W

Initial 60W fixed

Size compact 20cm x 10cm x 4.5cm  

UL Approval

UL1029, UL60950, IEC60950

Handled under RoHS and lead free regulation

 

Noise Level

Based upon Class B

Class B FCC Part18 Minimum leakage
Voltage

AC wide input

AC90V-AC264V
(Japan, US, Europe, China)
 
ON/OFF Method AC input ON-OFF    
1. Application
This specification shall apply to the lamp driver M66WBU-M to operate a ArcMeister™ 60W lamp.
This driver is designed and adjusted for the metal halide lamp

2. Standard Applied

The lamp driver is designed to meet these standards when mounted in the set.

[2-1] Safety Standard
UL60950, IEC60950

[2-2] EMI
FCC Part18 class B


3. General Specification
Category
Specification
Remarks

Cooling Method

Self-Cooling System

 

Operation Ambient Temperature

-20°C - 60°C (-4F-140F)  

Operational Relative Humidity

10%-90%RH no condensation

Storage Ambient Temperature

15°C-70°C (60F-158F)  

Storage Relative Himidity

5-90%RH no condensation

Operational Environment

Outdoor Use, Water Proof (IP57)

Output cable is not water-proof


4. Electrical Characteristics to Operate 100W
[4-1] INPUTS
Category
Specification
Remarks

Rated Input Voltage

AC100-120V/ 200-240V Frequency 50-60Hz

Input Voltage Range

AC90-264V Frequency 47-63Hz

Input Current

1.8A or less

At rated input, rated output, and ambient temperature at 77F

Input Power

125W +0%-10%

At rated input, maximum rated output, and ambient temperature 77F

Input Harmonic Component

EN61000-3-2 Class A

At rated input, rated output, and ambient temperature at 77F

 
[4-2] OUTPUTS
Category
Specification
Remarks

Operating Condition

Continuous Driving

Input Fluctuation
100V-120V/200V-240V
Load Fluctuation
45V-100V

Rated Output Power

DC 100W ± 5%
[When external VR is not connected]

At allowable input, according to lamp characteristics

Maximum Output Current

2.2A ± 0.2A At allowable input, at ambient temperature 77F.
The lamp must be able to maintain ignition.
Maximum Output Voltage
[Over Voltage Protection]
140V ± 20V

In starting only, at allowable input, ambient temperature 77F

Output Voltage at No load

380V ± 15V  
High Pulse
[High Pulse Voltage during ignition]
17.5-20.0KV  

Cycle of high-voltage pulse during ignition

7 cycles/sec  

High-Voltage Pulse Time Generated During Ignition

2.5 Seconds or less  
Instantaneous Power Failure "Performance Judgment Criterion B" of EN55022
100% reduction, 0.5 cycles
"Performance Judgement Criterion C" of EN55022
30% reduction, 25 cycles
100% reduction, 250 cycles
Depends on the condition of the lamp whether the lamp may be ignited or not.
Duration of ignition (inherent performance)

100% reduction
AC 90V: 1.5ms
AC180V: 39ms

 