Universal 90V-264V AC
Dimmable Range 60W-100W
Instant Start at 90% light in 20 s.
Hot re-strike in 1 s.
|
Download Datasheet
|
| |
| New Features |
| |
|
+ Durable in extreme temperature range :
-4°F - 140°F + Produces less noise + Low electricity
leakage + Instant re-strike |
|
|
Note: This product is capable to restrike itself in 45 sec.
however, it is not recommended that you re-start the ballast while the lamp is
still warmed up, as it will cause the electrode to wear out and as a result, it
will shorten the life of the lamps. The most ideal re-stike time in order to
maintain the lamp life is 45 sec. or longer.
|
|
|
Category |
Specification |
Remarks |
|
Water Proof
|
For outdoor use
|
Aluminium die-case model & urethane potting
|
|
| Temperature |
Tested and quaranteed to be used safely at sea and
outdoor
|
-20°C - 60°C |
|
|
Noiseless/Dustless
|
No fan required for lamp/ ballast
|
Self Cooling System
|
Lamp is securely protected
|
| Starter |
Instant re-strike
|
Lights up in 3 s. at max 15Kv
|
|
| Dimmer Function
|
Dimmable |
60W-100W
|
Initial 60W fixed
|
| Size |
compact |
20cm x 10cm x 4.5cm
|
|
|
UL Approval
|
UL1029, UL60950, IEC60950
|
Handled under RoHS and lead free regulation
|
|
|
Noise Level
|
Based upon Class B
|
Class B FCC Part18
|
Minimum leakage
|
| Voltage |
AC wide input
|
AC90V-AC264V (Japan, US, Europe, China)
|
|
| ON/OFF Method |
AC input ON-OFF
|
|
| |
| 1. Application |
|
This specification shall apply to the lamp driver M66WBU-M
to operate a ArcMeister™ 60W lamp. This driver
is designed and adjusted for the metal halide lamp |
|
|
|
| 2. Standard Applied |
|
The lamp driver is designed to meet these standards when
mounted in the set.
[2-1] Safety
Standard UL60950, IEC60950
[2-2] EMI FCC
Part18 class B
|
|
| 3. General Specification
|
|
Category |
Specification |
Remarks |
|
Cooling Method
|
Self-Cooling System
|
|
|
Operation Ambient Temperature
|
-20°C - 60°C (-4F-140F)
|
|
|
Operational Relative Humidity
|
10%-90%RH |
no condensation |
|
Storage Ambient Temperature
|
15°C-70°C (60F-158F)
|
|
|
Storage Relative Himidity
|
5-90%RH |
no
condensation |
|
Operational Environment
|
Outdoor Use, Water Proof (IP57)
|
Output cable is not water-proof
|
|
|
4.
Electrical Characteristics to Operate 100W [4-1] INPUTS |
|
Category |
Specification |
Remarks |
|
Rated Input Voltage
|
AC100-120V/ 200-240V
|
Frequency
50-60Hz |
|
Input Voltage Range
|
AC90-264V |
Frequency
47-63Hz |
|
Input Current
|
1.8A or less |
At rated input, rated output, and ambient
temperature at 77F
|
|
Input Power
|
125W +0%-10% |
At rated input, maximum rated output, and ambient
temperature 77F
|
|
Input Harmonic Component
|
EN61000-3-2 Class A
|
At rated input, rated output, and ambient
temperature at 77F
|
|
| |
| [4-2]
OUTPUTS |
|
Category |
Specification |
Remarks |
|
Operating Condition
|
Continuous Driving
|
Input Fluctuation 100V-120V/200V-240V Load
Fluctuation 45V-100V |
|
Rated Output Power
|
DC 100W ± 5% [When external VR is not connected] |
At allowable input, according to lamp characteristics
|
|
Maximum Output Current
|
2.2A ± 0.2A |
At allowable input, at ambient temperature 77F. The lamp
must be able to maintain ignition. |
Maximum Output Voltage [Over Voltage Protection] |
140V ± 20V |
In starting only, at allowable input, ambient temperature
77F
|
|
Output Voltage at No load
|
380V ± 15V |
|
High Pulse [High Pulse Voltage during ignition] |
17.5-20.0KV |
|
|
Cycle of high-voltage pulse during ignition
|
7 cycles/sec |
|
|
High-Voltage Pulse Time Generated During Ignition
|
2.5 Seconds or less |
|
| Instantaneous Power Failure
|
"Performance Judgment Criterion B"
of EN55022 100% reduction, 0.5
cycles "Performance Judgement Criterion C" of
EN55022 30% reduction, 25 cycles 100%
reduction, 250 cycles
|
Depends on the condition of the lamp whether the lamp may be
ignited or not. Duration of ignition (inherent performance)
100%
reduction AC 90V: 1.5ms AC180V: 39ms |
|
|
| | | |